RPS

Ship-to-Shore

  • Home
  • Products
    • Renewables
    • Transportation
  • Our Story
  • Contact
Resilient Power Systems (RPS) offers utility grade Shore Power Systems (HVSC) that reduces demand billing charges for ports, ensures interoperability between 50Hz , 60Hz , and 400Hz systems, and can eliminate up to 6 transformers typically found in competing ship to shore solutions, which  dramatically reduces footprint and construction costs. For large reefer loads, backup power can be provided from diesel generators or battery storage, which is part of the RPS Energy  Management System that seamlessly optimizes loads and generation for up to 40% reduction in power bills.
Picture
Grid Tie Converter
  • AC/DC bi-directional electrically isolated power control
  • Environmentally sealed power electronics
  • Single converter microgrid applications
  • Asynchronous coupling enables 50, 60, 400Hz, and DC
  • Cleans up power as it shares it between ports
  • Supports network during fault events
  • Connects directly to distribution line (no step up transformer)
  • No troublesome output filters
  • 2X voltage withstand rating
  • Meets UL 508, 1778, 347A, IEEE 1547
  • Continues to operate in harsh conditions
Lowers operating costs
  • Fully utilizes existing assets and increases their lifetime
  • More efficient power (no step up transformer and one converter)
  • Low maintenance (sealed electronics)
Small size and weight in weatherproof enclosure
  • Mobile or Stationary Applications
Required system components
  • Disconnect switch, fuse, and arrestor
Eliminates system components and planning
  • Step-up transformers
  • Output filters
  • Switchgear
  • Air conditioned building
Continuous local and remote control
  • DC to 1000Hz power systems
  • Fast response (>10kHz)
  • SEL RTAC Interface
  • EtherCat, Modbus, Ethernet, DNP3 Serial, IEC 60870-5
Operating Modes
  • Port power control (each AC phase independently controlled)
  • VAR compensation
  • Power Factor regulation
  • Voltage regulation
  • Active Filtering
  • Fault Support
  • Peak Shaving
  • Geomagnetic Induced Current mitigation
Stability
  • No inrush current and output filters
  • Low harmonics and flicker suppression
  • Avoids resonant frequencies
  • Rides through transient events
Optional energy storage and PV
  • Microgrid with one converter
  • UPS support
  • Three phase fault support, Peak shaving, Blackstart
  • One inverter controls hydrogen production and supply
  • Bi-directional battery storage

Picture
​​support@resilientpowersystems.com

SOUTHEAST DIVISION

Atlanta, GA
​404.593.0006

SOUTHWEST DIVISION

Georgetown, TX
​512.850.4889

​© 2020 Resilient Power Systems. All rights reserved. 
  • Home
  • Products
    • Renewables
    • Transportation
  • Our Story
  • Contact